A white cloud is pouring off the outdoor unit. The fan has stopped, it is 28 degrees out, and the air from your vents feels cooler than it did ten minutes ago. If you have a heat pump, that is usually the defrost cycle at work. Here is what is going on, how long it should take, and the signs that mean the unit needs a technician.
Why a Heat Pump Needs to Defrost
In winter the outdoor coil pulls heat out of cold air. The coil runs colder than the air around it, so moisture in the air condenses on it and can freeze. Trane puts the coil at typically 10 to 20 degrees colder than the outside air, which is why frost can start when it is only in the low 40s, though it is more common in the 20s and 30s. Lennox says frost can form at around 45°F.
Frost acts like a blanket on the coil. It blocks airflow, and the unit has to work harder to move the same amount of heat. To clear it, the system briefly switches into a mode that warms the outdoor coil and melts the ice. The outdoor fan usually stops while this happens.
Is the Steam Normal?
Usually, yes. The steam is ice melting and evaporating off a warm coil. Trane calls it perfectly normal, and Lennox describes it as water vapor.
A normal cycle tends to look like this:
- The outdoor fan pauses and you may hear a whoosh or a change in sound.
- White steam rises from the unit, then fades.
- The unit goes back to heating without you touching anything.
How long it lasts depends on the equipment. Trane says its demand-based cycles are usually 3 to 5 minutes. Lennox says a defrost typically takes 5 to 15 minutes. If your unit falls in that range and the ice is gone afterward, there is usually nothing to fix.
What You May Notice Indoors
During defrost the system is not sending heat into the house, so the air from the vents can feel cooler. Many heat pumps switch on backup heat strips during the cycle to limit the drop. On a system without backup heat, the indoor air may feel cooler until the unit returns to heating.
Steam Versus Smoke
Steam is white and thins out quickly. If you see dark or gray smoke or flames, get everyone out of the house right away and call 911 from outside. Do not stop to turn anything off. If you smell something burning but see no flames, turn the system off at the thermostat and call for service right away. Do not go looking for the cause yourself.
When Defrost Is a Problem
Defrosting itself is normal. These signs are not:
- A solid block of ice that is still on the unit after the cycle ends.
- Defrost cycles that seem constant, or that last longer and longer while frost and ice build up. Trane lists this as a reason to call.
- Steam that keeps rising with no end, or steam while ice stays put.
- Grinding or screeching from the outdoor unit.
Lennox notes that frequent or prolonged cycles can point to dirty coils, faulty sensors or low refrigerant. A homeowner cannot tell those apart from the yard, and refrigerant and electrical parts are not a DIY job.
What You Can Safely Do First
If snow has piled up, turn the system off at the thermostat first, then gently brush loose snow off the top and sides of the unit with a soft broom, from the ground, and keep the area around it clear. Keep hands and tools away from the fan and fins. Pay attention to the drainage spot under and around the unit too, since meltwater can refreeze into a slick patch where you walk. Do not chip at ice on the coil, and do not pour hot water over it. If the unit is heavily iced, leave the removal to a technician.
Indoors, check the air filter. ENERGY STAR suggests inspecting, cleaning or changing filters once a month on your furnace, central air conditioner or heat pump. A clogged filter makes any heat pump work harder, so it is worth checking.
How to Describe the Problem Before You Call
A technician can narrow things down faster if you bring a few observations. Jot these down the next time the unit defrosts:
- The outdoor temperature and whether it is damp, foggy or snowing.
- How long the steam lasts, and whether the fan restarts on its own.
- Whether ice is gone, thinner or unchanged when the cycle ends.
- How often it happens. Once or twice an hour in wet weather reads differently from every ten minutes.
- Any noises, and whether the house is holding its temperature.
- The make and model, which is printed on the data plate on the outdoor unit.
A photo of the coil taken after a cycle ends is also useful.
Cold Weather Performance and Backup Heat
A heat pump does not stop working when it gets cold, but models differ. ENERGY STAR certified air-source heat pumps are tested down to 5°F. ENERGY STAR also says to ask your contractor for an ENERGY STAR certified unit suited to your home if winter temperatures often drop below freezing, and that a good contractor will work with you on sizing and any integration with a backup heating system.
If you are deciding between a heat pump and a furnace for a Rhode Island home, our guide on heat pump or furnace walks through how ducts, your current fuel and backup heat shape the answer. For an existing system that ices up, steams without stopping or runs nonstop, see heat pump repair and service. Our heat pump installation page covers new systems.